SMA Sunnyboy Inverters

The Sunny Boy is the most successful solar inverter for grid connected PV-plants. There are plenty of good reasons for this. SMA has successfully been developing and manufacturing systems for energy conversion in railway applications and for industry for over two decades. This outstanding know-how is the basis for the Sunny Boy inverter.

Features: Components designed for 20 year performance, waterproof and dust resistant enclosure made of aluminum and stainless steel, outstanding ratings and reputation, 10 year warranty

Available Sizes: 2500, 3000, 4000, 5000, 6000, 7000

Documents:

Specsheets: SB3000US

Model Max. PV Power (watts) Max. DC Voltage (V) Max. DC Input I (A) Max. Effcy (%) CEC Effcy (%) Size (inxinxin) Weight (lbs) Op Temp Range (C)
SWR2500U 3000 240 12 94.1 93 17x12x9 71 (-25, 45)
SB3000US 3750 500 17 96.6 95.5 14x18x10 88 (-25, 45)
SB4000US 5000 600 18 96.8 96.0 14x18x10 88 (-25, 45)
SB5000US 6250 600 21 96.8 95.5 24x19x10 143 (-25, 45)
SB6000US 7500 600 25 97.0 96.0 24x19x10 143 (-25, 45)
SB7000US 8750 600 30 97.1 96.0 24x19x10 143 (-25, 45)

Place Order:

SWR2500U  $1,596.00   Qty:

SB3000US   $1,878.00   Qty:

SB4000US   $2,890.00   Qty:

SB5000US   $3,010.00   Qty:

SB6000US   $3,250.00   Qty:

SB7000US   $4,120.00   Qty:

Inverter Size Selection:

The inverter size is selected based on the power and voltage output of the panel array.  The power output of the array is the system size and is calculated as follows:

(system size) = (number of panels) x (power per panel)

The following could be used as a general guideline for inverter selection based on system size:

System size  2.0 - 3.0 kw  3.0 - 3.7 kw 3.7 - 5.0 kw 5.0 - 6.2 kw 6.2 - 7.5 kw 7.5 - 8.7 kw
Inverter SWR2500U SB3000US SB4000US SB5000US SB6000US SB7000US

The calculation of the voltage output of the system is a little tricky, becuase the voltage output of each panel increases with decreasing temperature.  The max voltage output depends factors like lowest temperature observed in the region, voltage temp coefficient, and no. of panels in series.  SMA has a very useful tool that does all those calculations for you.  Just click on the button below and input the information: